SENA ProBee-ZE20S-SEME User Manual
Page 73

ProBee-ZE20S-SExx User Guide Rev 1.8
73
6.4
ProBee SE Profiles Description
6.4.1
ProBeeSESI (Energy Service Interface)
The Energy Service Interface connects the energy supply company communication network to the
metering and energy management devices within the home. It routes messages to and from the relevant
end points. It may be installed within a meter, thermostat, or In-Premises Display, or may be a standalone
device, and it will contain another non-ZigBee communication module (e.g. power-line carrier, RF, GPRS,
broadband Internet connection).
6.4.1.1 Cluster Support
Table 6-2 ProBeeSESI Cluster Support
Server Side
Client Side
Basic
Identify
Time
Demand Response and Load Control
Price
Messaging
Key establishment
Key establishment
6.4.1.2 Attributes
Table 6-3 ProBeeSESI Attributes
Cluster
ID
Cluster name
Attribute
ID
Attribute name
Type
0x0000 Basic
0x0000 ZCL version
INT8U
0x0001 Application version
INT8U
0x0002 Stack version
INT8U
0x0003 Hardware version
INT8U
0x0007 Power source
ENUM8
0x0011 Physical environment
ENUM8
0x0012 Device enabled
BOOLEAN
0x0013 Alarm mask
BITMAP8
0x0014 Disable local config
BITMAP8
0x0003 Identify
0x0000 Identify time
INT16U