SENA ProBee-ZE20S-SEME User Manual
Page 54

ProBee-ZE20S-SExx User Guide Rev 1.8
54
End-point No.1: ProfileID-0x0109, DeviceID-0x0501
Server-side cluster: 0x0000 (Basic)
Client-side cluster: 0x000A (Time)
Server-side cluster: 0x0702 (Simple Metering)
Client-side cluster: 0x0703 (Messaging)
Client-side cluster: 0x0800 (Key establishment)
Server-side cluster: 0x0800 (Key establishment)
OK
5.4.2
Install Code Configuration
Each device can set Install Code optionally for enhanced Smart Energy security. Install Code is used to
generate Pre-configured link key of joining node. Please refer to the section 3.3 Setting up Install Code
for detail.
Example) Set Install Code to ProBeeSEID(end-device)
#Screen of ProBeeSEID(end-device)
AT+INSTALLCODE
# Get current Install Code
INSTALL CODE: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF # Now empty
OK
AT+INSTALLCODE=1122334455667788
# Set Install Code
OK
# Install code must be
# 6/8/12/16 byte hexadecimal
AT+INSTALLCODE
INSTALL CODE: 1122334455667788
# Successfully changed
OK
Example) Set Install Code to ProBeeSEME(end-device)
#Screen of ProBeeSEME(end-device)
AT+INSTALLCODE
# Get current Install Code
INSTALL CODE: FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF # Now empty
OK
AT+INSTALLCODE=1122334455667788
# Set Install Code
OK
# Install code must be
# 6/8/12/16 byte hexadecimal
AT+INSTALLCODE