SENA ProBee-ZE20S-SEME User Manual
Page 92

ProBee-ZE20S-SExx User Guide Rev 1.8
92
7.12.9 AT+CCMD or AT+CC
Description
Send client-side command message to destination node. (client-side command)
Execute
AT+DEST=
,AT+CCMD=
Response
OK
7.12.10 AT+FACTORYRESET or AT+FR
Description
Send ‘Factory Reset’ command(Basic cluster) to destination node. (client-side
command)
Execute
AT+DEST=
,AT+FACTORYRESET?
Response
OK
7.12.11 AT+IDENTIFY or AT+II
Description
Send ‘Identify’ command(Identify cluster) to destination node. (client-side
command)
Execute
AT+DEST=
,AT+IDENTIFY=
Response
OK
7.12.12 AT+IDENQUERY or AT+IQ
Description
Send ‘Identify Query’ command(Identify cluster) to destination node. (client-side
command)
Execute
AT+DEST=
,AT+IDENQUERY?
Response
OK
7.12.13 AT+TIME or AT+TM
Description
Get/Set Global Time. The format of time is determined by ATU value.
Execute
AT+TIME?
AT+TIME=
Response
OK
OK
Default
01-01-2000/00:00:00
Range
01-01-2000/00:00:00 - 02-07-2136/06:28:15
7.12.14 AT+TSYNC or AT+TS
Description
Read current time data from server-side Time Cluster (server-side Time Cluster)
Execute
AT+DEST=
,