beautypg.com

SENA ProBee-ZE20S-SEME User Manual

Page 84

background image

ProBee-ZE20S-SExx User Guide Rev 1.8

84

Default

ProBee-SExx

Range

Up to 16 characters

7.5

Network Formation and Join

7.5.1

AT+ASCAN or AT+AS

Description

Perform a scanning for existing network. It can take up to 5 seconds. (CAUTION:

It is possible to cause a link error if a node is a parent of an end-device.)

Execute

AT+ASCAN

AT+ASCAN=

Response

||||

List of the existing networks

OK

7.5.2

AT+ESCAN or AT+ES

Description

Perform a scanning for energy level of all channels. It can be used to avoid

interference. It can take up to 5 seconds. The RSSI energy level ranges from

approximately -100 to +127 in dBm. (CAUTION: It is possible to cause a link error

if a node is a parent of an end-device.)

Execute

AT+ESCAN

AT+ESCAN=

Response

|

List of the RSSI for each channel

OK

7.5.3

AT+DSCAN or AT+DS

Description

Perform a scanning for existing nodes in the current network. A coordinator or

router can have children nodes and they are presented by “CLDn”. It can be

possible to place some conditions such as scan duration, node type and node

name in order. The information of local node is presented by “*”. (CAUTION: A

ProBee-Z*10 with PTv1.2 or earlier cannot receive the response of AT+DSCAN

from any ProBee-Z*10 with PTv1.3 or later. It cannot receive from any ProBee-

Z*20, either. In this case, it is recommended to upgrade PTv1.2 to the latest

version.)

Execute

AT+DSCAN or

AT+DSCAN= or

AT+DSCAN=, or

AT+DSCAN=,,

Response

|||||

name>

List of the existing nodes and information

OK