beautypg.com

SENA ProBee-ZE20S-SEME User Manual

Page 101

background image

ProBee-ZE20S-SExx User Guide Rev 1.8

101

7.15.4 AT+SMFPENDTIME or AT+SFT

Description

Get/Set Metering Fast Poll Mode End Time. This value will be used in ‘Request

Fast Poll Mode Response’ command. The format of time is determined by ATU

value.

Execute

AT+SMFPENDTIME?

AT+SMFPENDTIME=

Response

OK

OK or ERROR

Default

01-01-2000/00:00:00

Range

01-01-2000/00:00:00 - 02-07-2136/06:28:15

7.15.5 AT+SMFPPERIOD or AT+SFP

Description

Get/Set Metering Fast Poll Mode Period. This value will be used in ‘Get Profile

Response’ command.

Execute

AT+SMFPPERIOD?

AT+SMFPPERIOD=

Response

OK

OK or ERROR

Default

00

Range

00 - FF

7.15.6 AT+SMENDTIME or AT+SET

Description

Get/Set Metering End Time. This value will be used in ‘Get Profile Response’

command. The format of time is determined by ATU value.

Execute

AT+SMENDTIME?

AT+SMENDTIME=

Response

OK

OK or ERROR

Default

01-01-2000/00:00:00

Range

01-01-2000/00:00:00 - 02-07-2136/06:28:15

7.15.7 AT+MSGETLAST or AT+MGL

Description

Send ‘Get Last Message’ command(Messaging cluster) to destination node.

(client-side command)

Execute

AT+DEST=

,

AT+MSGETLAST

Response

OK or ERROR