SENA ProBee-ZE20S-SEME User Manual
Page 74

ProBee-ZE20S-SExx User Guide Rev 1.8
74
0x000A Time
0x0000 Time
UTC_TIME
0x0001 Time Status
INT8U
0x0800 Key establishment (Server Side) 0x0000 Key establishment suite
ENUM16
0x0800 Key establishment (Client Side)
0x0000 Key establishment suite
ENUM16
6.4.1.3 Commands
Table 6-4 ProBeeSESI Commands
Cluster
ID
Cluster name
Comm
and ID
Command name
Pay
load
AT Command
0x0000
Basic
(Server-side)
0x00
Reset to Factory Defaults
-
AT+FACTORYRESET
0x0003
Identify
(Server-side)
0x00
Identify
2
AT+IDENTIFY
0x01
Identify Query
-
AT+IDENQUERY
0x0700
Price
(Server-side)
0x00
Publish Price
51 AT+PRSETPUBLISH
0x01
Publish Block Period
17
-
0x0701
Demand
Response
and
Load Control
(Server-side)
0x00
Load Control Event
23 AT+DLLOADCTRL
0x01
Cancel Load Control Event
12 AT+DLCANCELLOAD
0x02
Cancel All Load Control Events
1
-
0x0703
Messaging
(Server-side)
0x00
Display Message
V
AT+MSDISPLAY
0x01
Cancel Message
2
AT+MSCANCEL
0x0800
Key
establishment
(Server-side)
0x00
Initiate Key Establishment
Request
23 AT+CBKESTART
0x01
Ephemeral Data Request
22
0x02
Confirm Key Data Request
16
0x03
Terminate Key Establishment
4
-
6.4.2
ProBeeSEID (In-Premises Display)
The In-Premises Display device will relay energy consumption data to the user by way of a graphical or
text display. The display may or may not be an interactive device. At a minimum at least one of the
following should be displayed: current energy usage, a history over selectable periods, pricing information,
or text messages. As an interactive device, it can be used for returning simple messages for interpretation
by the recipient (e.g. “Button A was pressed”). The display may also show critical pricing information to
advise the customer when peaks are due to occur so that they can take appropriate action.