Troubleshooting, Chapter 6 troubleshooting, Error messages – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1813 User Manual
Page 48

48
PNEG-1813 Electronic Distributor Control
6. Troubleshooting
Error Messages
Message
The value entered was greater than the allowable deviation from the original position. Please enter
a value between “X” and “Z”.
Reason
This error is displayed when a position count value outside the acceptable range is entered while in the
“Modify Spout Position” screen.
Remedy
Enter a value between “X” and “Z” on the “Modify Spout Position” screen.
Message
Reason
This message is displayed as you enter the “Configuration Setup” screen.
Message
The home proximity sensor was not detected. The homing process failed. Please check for proper
operation of the sensor.
Reason
This error is displayed when attempting to perform a “Homing” operation and the controller fails to receive
a proximity sensor signal before the time out period is reached.
Remedy
Check wiring, wiring connections and proximity sensors. Repair or replace as necessary.
Message
The position feedback does not match expected behavior. Please check for proper operation of
the encoder.
Reason
This error is displayed if the spout does not reach the desired position count while performing a
“MOVE” operation.
Remedy
Check wiring, wiring connections and encoder. Repair or replace as necessary.
WARNING
Any changes to the settings will alter factory defaults and may result in damage
to equipment. To exit without changes, select CLOSE and then OK.