PNEG-1813 Electronic Distributor Control

6. Troubleshooting

Error Messages

Message

The value entered was greater than the allowable deviation from the original position. Please enter
a value between “X” and “Z”.

Reason

This error is displayed when a position count value outside the acceptable range is entered while in the
“Modify Spout Position” screen.

Remedy

Enter a value between “X” and “Z” on the “Modify Spout Position” screen.

Message

Reason

This message is displayed as you enter the “Configuration Setup” screen.

Message

The home proximity sensor was not detected. The homing process failed. Please check for proper
operation of the sensor.

Reason

This error is displayed when attempting to perform a “Homing” operation and the controller fails to receive
a proximity sensor signal before the time out period is reached.

Remedy

Check wiring, wiring connections and proximity sensors. Repair or replace as necessary.

Message

The position feedback does not match expected behavior. Please check for proper operation of
the encoder.

Reason

This error is displayed if the spout does not reach the desired position count while performing a
“MOVE” operation.

Remedy

Check wiring, wiring connections and encoder. Repair or replace as necessary.

WARNING

Any changes to the settings will alter factory defaults and may result in damage
to equipment. To exit without changes, select CLOSE and then OK.