beautypg.com

Wire and fitting selection recommendations – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1813 User Manual

Page 20

background image

3. Installation

20

PNEG-1813 Electronic Distributor Control

Wire and Fitting Selection Recommendations

NOTE: The power cable, encoder cable, proximity sensor cables, motor cable and electrical fittings are
not supplied with the electronic distributor control. The following recommendations must be followed
when selecting wire types and electrical fittings:

For the proximity sensor and encoder cables from the junction box to the control panel, use ten (10)
conductor or greater shielded cable, 22 AWG or larger and rated for the environment. If the wiring is run
outside of conduit, it should be rated for UV.

For the motor cable from the motor to the control panel, use four (4) conductor cable, shielded, 16 AWG
or larger and rated for the environment. If the wiring is run outside of conduit, it should be rated for UV.

All conduit and fittings should be outdoor-rated to keep things adequately sealed.