4. Operation Procedures

44

PNEG-1813 Electronic Distributor Control

Homing Warning

To help ensure accurate positioning of the distributor a homing warning will display when the number of
times the distributor is repositioned is equal to the homing interval. This message will occur every time that
a spout move is attempted until the homing procedure is completed. The user will be given two (2) options:
“Home Now” and “Home Next Move”.

(See Figure 4V.)

Figure 4V Homing Warning

Home Now

Select to perform the homing calibration immediately. The user interface will return to the “MAIN”
screen and “Homing” will flash ON and OFF in yellow. After homing is complete, the spout will return to
the selected position.

Home Next Move

Select “Home Next Move” to skip the homing operation and move to the selected position. The user
interface will continue to prompt you to home the unit during every subsequent move until homing
is performed.