4-33

Mapping with Veris Datalogger


Connect EC signal cable and power cords to ports on rear of OpticMapper/EC Controller, connect
the GPS to the GPS in of the OM Comm. cable, then connect the serial output of the OM Comm.
to the EC port on the DataLogger. Attach the pH controller to the pH port on the datalogger.

Press any button to continue

Figure 83

Press 1)Data Acqstn

Figure 84

Press 3)EC+OM+pH

Figure 85

Press any key to continue

Figure 86 The DataLogger is displaying the map file number it is creating, in case you want to
record it along with any other information about the field. Press any key to begin new map file.
After starting the file, pressing the #4 key will stop the file. If DataLogger freezes at the screen
shown in Figure 86, check formatting of SD card

—must be FAT format.


If memory card was not inserted during boot-up, the following screen will appear:

Figure 87

Install card and re-start DataLogger. NEVER REMOVE CARD WHILE LOGGING DATA