beautypg.com

Veris Technologies MSP3 - Operating Instructions User Manual

Page 49

background image

Pub. #OM17-MSP3

4-29

Once unit is level, lower sampling mechanism completely, drive forward 10-

20’ (3-6 m) to create

soil core. To measure depth of soil core being collected, brush away soil from cutting shoe.
Measure from soil surface to top of cutting shoe. This is the depth of sampling. To increase
sampling depth, shorten ratchet jack; to decrease sampling depth, lengthen ratchet jack. Re-
leveling unit with adjustable top link may be required.

Figure 73

Note: if MSP is equipped with EC Module and EC data is being collected along with pH data,
adjusting the overall height of the unit will affect coulter-electrode depth. If deeper soil sampling is
desired, and shortening ratchet jack would result in excessive coulter-electrode depth, remove
sampler shank pins and lower shank to lowest setting. If shallower soil sampling is required, and
lengthen ratchet jack results in inadequate coulter-electrode depth for EC data collection, raise
sampler shank to highest setting.


Figure 74


Once EC coulter depth and sampling depth are satisfactory, adjust other components in this
sequence:

1. Scraper adjustment: in manual mode hydraulically raise the sampling shoe to maximum height.

Adjust scraper until cutting shoe clears scraper blade when sampler shank is fully raised.

pull adjustment pins and
lower shank if deeper
sampling is needed (and
EC coulter depth is
satisfactory)

sampling depth
is measured
from top of
cutting shoe to
soil surface