Veris Technologies MSP3 - Operating Instructions User Manual
Page 31
Pub. #OM17-MSP3
4-11
The EC OM pH-MSP3 Mapping software will automatically detect which ports the Veris
OpticMapper /EC Controller and pH Controller are connected to, and begin communicating. If
either is not detected, the software will wait 45 seconds for the connection of the electronics and
search again; this will repeat until both instruments are connected. If the electronics are not found,
unplug the serial or USB cables and reconnect them to the PC. If the connections are still not
made, refer to SoilViewer troubleshooting. The conditions for mapping and storing the data are as
follows. The user must be going a speed greater than 1 mph, there must be a GPS signal
received that includes position and speed (GGA and either VTG or RMC), the OM/EC Comm Light
must be green, indicating the PC and OpticMapper with EC Surveyor are communicating properly,
and either of the EC values has to be greater than -1.
Before mapping, run the OM system check and pH calibration to ensure everything is
operating correctly. pH controller settings can be modified to adjust the wash and cycle
times for specific field conditions.
Figure 34
Pinch point hazard: to prevent injury, stand clear when raising or lowering any part of the
Veris MSP3.
Install all transport locks before transporting or working underneath.
Always use the service stands when working underneath the MSP3.
After clicking on EC OM
pH- MSP3 the user will
be prompted to input the
EC file name. All OM
and pH files will be
named the same as the
EC. Files may be
appended to by
selecting a previously
created VSEC file.