beautypg.com

Veris Technologies MSP3 - Operating Instructions User Manual

Page 43

background image

Pub. #OM17-MSP3

4-23

To help insure the quality of your data, please follow these guidelines:

1. Generate and view maps frequently, especially prior to deleting data from Instrument.

2. Listen for auditory alarm from DataLogger, indicating data collection has been interrupted.

3. View DataLogger screen or SoilViewer map frequently during data collecting; watch for:
Negative readings in the Shallow and Deep or excessive noise in the OpticMapper data.
Sensor readings should fluctuate gradually as you drive across the field, relating to

soil changes. If readings change erratically, or show values not typical of soil
in the area, perform tests 4-6 below.
In SoilViewer, watch for streaks, stripes, unnatural patterns, and missing data points.


4. Perform electrical continuity test on implement wiring:

at least once a day during mapping season
every 10 hours of mapping
after extended periods of non-use
after replacing or repairing coulter-electrode components or wiring
whenever readings are questionable


5. Perform Signal Testing Procedures #1 and #2:

at least once a day during mapping season
every 10 hours of mapping
after extended periods of non-use
whenever readings are questionable


6. Perform black/white reference OM System Check and OM Test Load Procedure #1

Before mapping every field
Whenever readings are questionable

7. Keep all electrical connections dirt and moisture-free

8. Limit speeds in rough or rocky field conditions. This will improve data quality, and will also

lengthen the service life of the implement components. NEVER EXCEED 15 M.P.H. FIELD
SPEED WHEN MAPPING EC/OM. NEVER EXCEED 7.5 M.P.H. WHEN MAPPING PH.