4-19

Adjustable Wing Extensions
This feature allows the re-positioning of the electrodes to fit various bed and crop configurations.
Adjustment is made by loosening the jam nuts and set screws located on the lower front of each
side of the toolbar, adjusting the toolbar wing extensions, and re-tightening the set screws. Veris
suggests setting the toolbars at either the maximum or minimum setting, not at a point in between.
A limiter bolt determines full extension, so they cannot extend to the point at which the outside
coulters disconnect from the main frame. Important

– do not attempt to combine maps in which two

different investigative depths are used.

Figure 53

Pinch point hazard: to prevent injury, stand clear when raising or lowering any part of the

Veris MSP3.

Install all transport locks before transporting or working underneath.
Always use the service stands when working underneath the MSP3.

Figure 54

Figure 55

set screws and
jam nuts