Acnodes FPC 6084 User Manual
Page 78

661 Brea Canyon Rd., Suite 3
Walnut, CA 91789
tel: 909.598.7388, fax: 909.598.0218
© Copyright 2011 Acnodes, Inc.
All rights reserved. Product description and product specifications
are subject to change without notice. For latest product information,
please visit Acnodes’ web site at www.acnodes.com.
FPC 6065 / 6084
9-24 bits, 1 ppc (Default)
18, 24 bits, 2 ppc
Refresh Rate [60Hz]
The Refresh Rate option can only be configured if the Flat Panel Type option is not set to Auto. Use the
Refresh Rate option to set the screen refresh rate required by the panel connected to the system. Check
the documentation that came with the panel before setting this option. The Refresh Rate options are:
60Hz (Default)
70Hz
72Hz
75Hz
85Hz
90Hz
100Hz
HSYNC Polarity [High]
The HSYNC Polarity option can only be configured if the Flat Panel Type option is not set to Auto. Use the
HSYNC Polarity option to set the polarity of the HSYNC signal to the panel. The HSYNC Polarity options
are:
High
Low (Default)
VSYNC Polarity Active [Low]
The VGSYNC Polarity Active option can only be configured if the Flat Panel Type option is not set to Auto.
Use the VGSYNC Polarity Active option to set the polarity of the VSYNC signal to the panel. The VGSYNC
Polarity Active options are:
High
Low (Default)
SHFCLK Active Period [Free Running]
Use the SHFCLK Active Period option to set the SHFCLK. The SHFCLK Active Period options are:
Active Only
Free running (Default)
LP Active Period [Free Running]
Use the LP Active Period option to set the LDE/MOD signal to the panel. The LP Active Period options
are:
Active Only
Free running (Default)