Toshiba Strata DK 16 User Manual
Page 97

PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS
SECTION 100-816-302
MARCH 1993
2-73
NOTES:
1. For more information, see the instructions preceding the record sheets.
2. Initialized data assigns a Ring Transfer Recall Time of 032 seconds to all ports.
3. To enter a range of ports, key in the sequence:
4. Ring Transfer Recall Time is the time it takes to recall a station that originates an unanswered or busy (camped-on)
transferred call.
5. Ring Transfer must be allowed (Program 10-1, LED 07 ON) for transfer recall to function; otherwise Recall will be immediate.
6. Ring Transfer to stations in the Do Not Disturb Mode is not allowed; recall will be immediate if it is attempted—no matter what
the Program 37 recall time is.
PROGRAM 37
RING TRANSFER (CAMP-ON) RECALL TIME
3
7
P
S
H
H
Z
Z
S
HOLD TIME = Ring Transfer Recall Time
Enter the Ring Transfer Recall
Time (in seconds). The acceptable
range is 011 ~ 999 seconds. Use
three digits.
SELECT = Logical Port Number (00~19)
Enter the number of the port that
needs a Ring Transfer Recall time
assigned. See Note 3 for
entering a range of ports.
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Logical
Port
16
17
18
19
Hold
Time
NOTE: Shaded areas apply to DK16 only
Low port
High port