PROGRAMMING PROCEDURES-INTRODUCTION
SECTION 100-816-301
MARCH 1993
1-5
TABLE 1-B (continued)
MULTIDIMENSIONAL PROGRAM: PROGRAM 30,
STATION CLASS OF SERVICE
Step
#
Press...
BUTTONS
+ LED keys
Action description
LCD RESPONSE ...
6.
7.
HOLD
Secure data in system programming.
30 SELECT = (00 ~ 19)
DATA PROGRAMMED
8.
SPKR
Prepare system for another selection (go back to
step 5), or exit Program 30 (continue with step 9).
30 SELECT =
9.
# # HOLD
Secure Program 30 data in system memory.
30 SELECT = ##
DATA PROGRAMMED
10.
SPKR
Exit Program 30. Enter another program number or exit
programming mode (go to step 11).
System beeps to indicate it is exiting Program 30.
PROGRAM =
11.
# # HOLD
Exit programming mode.
NO. OF STATION (10 ~ 29)
JAN 20 SUN
06:58
LED keys 01 ~ 20 (continued)
LEDs 12 and 13 ON: Digital Telephone Handset
Receiver Volume
LED 14 ON: Account Codes Verified
LED 15 ON: Verified Account Code Revision Authority
LED 16 ON: Traveling Class of Service Code Revision
Authority
LED 17 ON: Do Not Disturb Override Allowed
LED 18 ON: Executive Override Allowed
LED 19 ON: Privacy Override Allowed
LED 20 ON: Not Used
If programming a port range, the LED indications are
as follows:
¥
¥
¥
LED-ON, all ports in range are enabled for that item.
LED-OFF, all ports in range are disabled for that item.
LED-FLASHING, some ports in range are enabled and
some ports are disabled.