PROGRAMMING PROCEDURES-INTRODUCTION
SECTION 100-816-301
MARCH 1993
1-12
TABLE 1-F
PROGRAM 00
SOFTWARE CHECK AND REMOTE MAINTENANCE SECURITY CODE ASSIGNMENTS
Step
#
Press...
BUTTONS
+ LED keys
Action description
LCD RESPONSE ...
1.
Use an LCD digital or electronic telephone
with a programming template.
JAN 20 SUN
NO. OF STATION (10 ~ 29)
06:43
2.
*
#
*
# 1
*
2
*
3
PROGRAM MODE
Enter programming mode.
3.
SPKR 0 0 HOLD
PROGRAM = 00
DATA STORE
Speaker beeps to indicate when to enter program
number. Access Program 00.
4.
SPKR
00 SELECT =
Prepare system for a selection.
5.
0
00 SELECT = 0
VERSION = QMA (DK8 ONLY)
--OR--
VERSION = PSSA (DK16 ONLY)
= SOFTWARE VERSION ID
View the software version. This attribute is not editable.
OR
Select one of the following attributes:
A.
1
00 SELECT = 1
PASSWORD = 0000
Define the Level 1 remote maintenance security code
from the System Record Sheet (four digits max.). Level 1
allows remote access to all programs and data.
Default Level 1 security code is "0000."
OR
B.
2
00 SELECT = 2
PASSWORD = 0000
Define the Level 2 remote maintenance security code
from the System Record Sheet (four digits max.). Level 2
allows remote entry to Programs 30 ~ 39 and 77 ~ 89
only. Default Level 2 security code is "0000."
OR
C.
8
00 SELECT = 8
SUM = XXXXXXXXX
View the software RAM Checksum. This attribute is not
editable. The default checksum may change.
OR
D.
9
00 SELECT = 9
COUNTER = XXXX
View the Power Supply Cycle Counter. This attribute is
not editable. The counter indicates the number of times
power is removed from the system after
was initialized via Program 90.
E.
6.
HOLD
00 SELECT = (0,1,2,8, or 9)
DATA PROGRAMMED
Secure data in system programming.
(Only works for “1” and “2”)
7.
SPKR
00 SELECT =
Prepare system for another selection (go back to
step 5), or exit Program 00 (continue with step 8).
Program 00
.
.
.