Toshiba Strata DK 16 User Manual
Page 70

PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS
SECTION 100-816-302
MARCH 1993
2-46
PROGRAM 03
DK16 FLEXIBLE PCB SLOT ASSIGNMENTS
Slot 04 ~ 06 (Expansion Unit assignment criteria):
• Only one type of station card (except for KCDU) is allowed
(maximum); 1-PDKU, or 1-PEKU, or 1-PESU, or 1-PSTU, or
2-KCDUs.
• If KCDU is installed: PDKU, PEKU, PESU, PSTU, or PCOU
cannot be installed; PIOU or another KCDU can be in-
stalled.
• Station and CO line PCBs should be installed in slots 04
and 05.
• PIOU should be installed in slot 06.
• Slot 07 should be left empty.
NOTES:
1. See instructions in Table 1-E (Section 100-816-301) to input the data
from this record.
2. Initialized data.
3. PESU circuits: 1 and 2, standard telephones; 3 and 4, not used; 5 ~ 8,
electronic telephones. Total 8 station ports used in software.
4. OCA or PDIU-DI(2)/PDIU-DS will function only with Code 62 or 64
(Base Unit digital telephone circuits and PDKU).
5. System Power must always be cycled after running Program 03.
6. Off-hook Call Announce (OCA) and Data Interface Units (PDIU-DI(2)
and PDIU-DS) will not work in Slots 06 and 07.
7. KCDU does not support DSS connection. PDIU-DI(2)/PDIU-DS or OCA
will function with Code 66 only.
8. Digital telephones cannot support OCA and PDIU-DIs/PDIU-DI2s
simultaneously.
9. Special PCB codes are not required for ADM or DDCB installation.
10. This program is not necessary for DK8.
0
3
When Complete:
POWER OFF
for 5 sec. then
POWER ON
To Store Data
P
S
H
H
Z
Z
S
COMMON
CONTROL
COMMON
CONTROL
WITH K4RCU
PIOU/PIOUS
PEKU
PEKU
W/EOCU
PEKU
W/DSS
PEKU
W/EOCU,
DSS
PESU
PESU
W/EOCU
KSTU AND
PSTU
BASE UNIT CO
CKTs AND
PCOU
BASE UNIT
DKT CKTs
AND PDKU
4
BASE UNIT
DKT CKTs
AND PDKU
4
W/DIU or OCA
BASE UNIT
DKT CKTs
AND PDKU
4
WITH DSS
(WITH OR
WITHOUT DIU
OR OCA)
KCDU
7
KCDU
7
OCA or DIU
NONE
91
92
41
21
22
23
24
25
26
31
11
61
62
64
65
66
00
PCB CODE
Reference Table
00
91
2
—
—
01
00~07
2
02
11
2
01~04
2
03
31
2
KSTU
08~11
2
04
05
06
07
BASE UNIT/
FIXED SLOTS
SLOT NO.
PCB CODE
OPTIONS
STA. PORT #s
CO/LINE#s
NONE
NONE
NONE
8/STA.
8/STA.
8/STA.
8/STA.
See Note 3
See Note 3
8/STA.
4/CO
8/STA.
8/STA.
8/STA.
2/CO
4/STA.
2/CO
4/STA.
NONE
SELECT = Slot Number
PCB FIXED
SLOT
PORTS/TYPE
CODE
CARD = PCB Code
See Reference Table
5
Digital
Ckts
EXPANSION UNIT
FLEXIBLE SLOTS
61
2
Common
Control
CO
Ckts
PCB TYPE/
FIXED SLOT