Toshiba Strata DK 16 User Manual
Page 137

2-113
PROGRAMMING PROCEDURES-INSTRUCTIONS/SYSTEM RECORDS
SECTION 100-816-302
MARCH 1993
NOTES:
1. For more information, see the instructions preceding the record sheets.
2. Program 40 denies CO line access via LCR and denies all other access methods.
3. Program 41 allows CO line access via LCR but denies all other outgoing access methods:
(CO line number 701 ~ 708, Pooled group 81 ~ 88, Line or Pooled Line Grp buttons).
4. Initialized data: All LEDs OFF.
5. To prevent Toll Restriction from being defeated because of K4RCU or QRCU time-out, Toll Restricted standard
telephones should be forced to dial outgoing calls via LCR.
LCR CO LINE PROGRAMING
Line Group
1 (81)
2 (82)
3 (83)
4 (84)
5 (85)
6 (86)
7 (87)
8 (88)
CO Line Type/Comments
CO Line Group Reference Chart
CO Lines in
Group (1 ~ 8)
1) Use to assign CO lines in groups per the reference chart below.
2) Use to allow CO lines access to stations using LCR for outgoing calls.
3) Use to deny outgoing CO line access except for LCR access.
Program 16
Program 40
Program 41
Important: Area code and office code structure must be defined by
(Toll Restriction Dial Plan) for LCR to work properly.
Program 45-1
4) Use to enable the dial plan that is appropriate for the area where LCR calls will originate.
Program 45-1
NOTE: Shaded areas apply to DK16 only
H
Z
Z
5
P
S
H
S
0
SELECT = 1
Press Button/LEDs for each LCR parameter.
1
LED
1
2
3
4
5
Enable System LCR
Not Used
555 LDI Route Per Program 50-4
Dial Tone After LCR Access
Warning Tone Last Choice Route No.
X
LED On
No LCR
Not Used
Per Area Code Table
Silent
No Warning Tone
LED Off
PROGRAM 50-1
LCR PARAMETERS