Chapter 9 Operation and Maintenance

Diskette drive A error

Check the settings of [Diskette A] or [Diskette B] on the"8.2.2
Main Menu" ( pg.226)
of the BIOS Setup Utility. Check to see
whether the floppy disk drive cable is connected properly.

Diskette drive B error

Incorrect Drive A - run SETUP

Correct the settings of [Diskette A] or [Diskette B] on the"8.2.2
Main Menu" ( pg.226)
of the BIOS Setup Utility.

Incorrect Drive B - run SETUP

System Cache Error - Cache disabled

Stop the server once, then restart it again. If the message still
appears, check the error log and replace the CPU if it is at fault.
Or the baseboard must be replaced. Contact an office listed in
the "Contact Information" of the "Start Guide".

System memory exceeds the CPU's caching
limit

EISA CMOS not writable

Power off the server and turn it back on. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of the "Start Guide".

DMA Test Failed

Software NMI Failed

Fail-safe Timer NMI Failed

Verify CPU Frequency selection in Setup

Power off the server and turn it back on. If the message still
appears, check the error log and replace the CPU if it is at fault.
Or the baseboard must be replaced. Contact an office listed in
the "Contact Information" of the "Start Guide".

System Management Configuration changed

If this is displayed right after changing the hardware
configuration, disregard it. If the same message is displayed
again, change the [Reset Configuration Data] setting to [Yes] on
the"8.2.5 Advanced Menu" ( pg.230) of the BIOS Setup
Utility.

Invalid System Configuration Data

Change [Reset Configuration Data] on the"8.2.5 Advanced
Menu" ( pg.230) to [Y
es] in the BIOS Setup Utility.

Invalid System Configuration Data - run
configuration utility

Patch for installed CPU not loaded. Please run
the bios flash update diskette.

Contact an office listed in the "Contact Information" of the
"Start Guide".

The system performed an emergency
shutdown.

The system shut down due to some reason; refer to the event log
for details.

Manually-operated Retention Latch is not
closed at Hot-Plug PCI slot n

The latch of the PCI slot is opened. Close the latch.

CNR Plug and Play EEPROM contents are
damaged.

A CNR error. Power off the server and turn it back on.

If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of the
"Start Guide".

CNR version newer than motherboard, some
CNR functionality may be lost.

CNR and AC97 Version do not match, AC97
functionality of CNR ignored.

Illegal AC97 configuration, AC97 Audio and
Modem functions disabled.

Illegal AC97 configuration, AC97 Modem
function disabled.

CNR LAN Interface not compatible with
Motherboard, LAN function disabled.

USB version required by the CNR is not
supported by the motherboard. The CNR USB
functions will operate at lower spe

CNR EEPROM PCI Configuration data size
mismatch

table: List of POST error messages

Message

Description