5.6.4 Cautions on Using the Teaming (SLB (Auto-Fallback

Disable)) Function

When a primary adapter is recovered from a failure during standby operation, auto-fallback is not

performed for the primary adapter. Communication is continued with the standby adapter.

To return to the communication using the primary adapter, perform the following operation.

1

Start up BACS. The procedure differs depending on the OS being used.

For Windows Server 2003

1. Click [Start]

→ [Control Panel] → [Broadcom Control Suite 2].

For Windows 2000 Server

1. Click [Start]

→ [Settings] → [Control Panel].

The [Control Panel] window appears.

2. Start up "Broadcom Control Suite 2".

2

Check that communication is performed with the [standby adapter] on the

Teamed Up adapter tree.

The currently communicated adapter is displayed with a

mark.

3

Check that the primary adapter is running properly on the Teamed Up adapter

tree.

The primary adapter that is running properly is displayed with a

mark.

If the primary adapter is not running properly, a

mark is displayed.