Chapter 8 Hardware Configuration/Utilities
8.2.10 IPMI Submenu
Appears when [IPMI] is selected from the [Advanced] menu.
Configures the Baseboard Management Controller (BMC).
Wake Up Time
-
Configures the power-on time setting using the
timer.
Wake Up Mode
-
Specifies the power-on interval using the timer.
Power Failure Recovery
• Always Off
• Always On
• Previous State (at the
time of purchase)
Sets the server power status after system down due
to power failure or after power recovery by the
UPS.
Note:
Set this item to [Always ON] when a UPS is
used.
table: Items on the IPMI Submenu
Item
Setting
Description
SEL Load
-
Displays the stored SEL in percentage.
Clear System Event Log
• Disabled (at the time of
purchase)
• Enabled
Deletes logs stored in System Event Log (SEL).
(Do not delete SEL from this menu.)
Event Log Full Mode
• Overwrite (at the time of
purchase)
• Maintain
Configures the log when full SEL is indicated.
BMC Time Sync
Enabled (Fixed parameter)
Sets whether or not to synchronize the BMC
internal timer with RTC at startup.
table: Items on the Power On/Off Submenu
Item
Setting
Description
Item Specific Help
F1
Esc
Select Item
Select Menu
Change Values
Select Sub-Menu
-/+
Enter
Info
Exit
F9
F7
Setup Defaults
Previous Values
PhoenixBIOS Setup Utility
Advanced
SEL Load nn%
Clear System Event Log [Disabled]
Event Log Full Mode: [Overwrite]
BMC Time Sync: [Enabled]
System Event Log
SDRR Browser
LAN Settings
IPMI