beautypg.com

4 defective cpu disconnection function, Removing the defective cpu – Primera Technology Fujitsu Tape Drive RX300 S2 User Manual

Page 181

background image

181

PRIMERGY RX300 S2 User’s Guide

Inst
allin
g I

nte

rn

al O

pti

ons

7

7.3.4 Defective CPU Disconnection Function

This server is equipped with the defective CPU disconnection function.

This function disconnects the CPU judged to be defective (abnormal) during Power On Self Test

(POST) to start the server. On two-CPU servers, if one CPU is defective, the other CPU starts up the

server.

The defective CPU can be checked with the information displayed during POST.

■ Removing the Defective CPU

Remove the defective CPU, referring to "

How to Remove a CPU" ( pg.180).

After replacing the CPU, start the BIOS Setup Utility and select the [Server] menu "8.2.13 CPU Status

Submenu" ( pg.244) to check that [CPU n Status] (n is the number of the CPU) is set to [Enabled]. If

the item is set to [Disabled] or [Failed], change the setting to [Enabled]. If it is not set to [Enabled], the

server will start with the CPU recognized as being defective and constantly disconnected.

To use the new CPU, set the item to [Enabled] for releasing the failed CPU status at the next startup.