ACCULINK 336x E1 NTU

C-6

December 1996

3360-A2-GB20-20

Table C-2

(4 of 4)

Port Configuration Options

Far-end: Disab
Next Disab Maint Prev

Far-End Performance Statistics. Specifies whether to monitor for far-end performance report messages (PRMs) and
maintain far-end performance registers for a particular port.

Disab – Disables far-end performance statistics.

Maint – Monitors the port’s EDL for PRMs and maintains far-end performance statistics.

NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.

NOTE: This configuration option is not available if

EDL is disabled.

NOTE: If the local E1 NTU is configured to maintain far-end performance statistics, then the remote device must be

configured to send near-end performance statistics.

Mgmt Link: Disab
Next Disab SNMP Prev

EDL Management Link. Specifies whether the EDL management link is enabled for a particular port. Selecting SNMP
allows SNMP management traffic to flow over the 4 kbps in-band data link provided by EDL.

Disab – Disables the port’s EDL management link.

SNMP – Enables the port’s EDL management link.

NOTE: This configuration option is only available on 2-port and 4-port E1 NTUs.

NOTE: This configuration option is not available if

EDL is disabled or FDL is enabled for SNMP.

NOTE: If the local E1 NTU’s EDL is enabled, then the remote device’s EDL must also be enabled.