Power-Up Self-Test

After you connect the E1 NTU to a power source, the

unit performs the power-up self-test to ensure that it is in
good working order. The E1 NTU performs this test on
itself upon power-up or after a device reset, unless it has
been disabled by the Self-Test configuration option (see
Appendix C,

Configuration Options

).

The self-test includes a basic processor test, a limited

memory test, a code checksum test, and basic verification
tests of the internal components. The front panel LCD
displays the progress and pass/fail status of these
power-up tests.

The power-up self-test consists of the following steps:

1. Once the E1 NTU is plugged in, the In Progress

screen appears and the Fail LED blinks ON and
Off continuously.

F1

Self-Test:
In Progress

F2

F3

495-14747

OK

TEST SIG1

SIG2

OOF

NETWORK

RXD

ALRM

SIG

ALRM PDV

OOF

BPV

FAIL

CTS

RTS

TXD

DTR

2. All the LEDs then start to flash simultaneously in

the pattern twice ON, then Off. Then, the LCD
begins to flash characters and numbers in the same
pattern, alternating with the flashing LEDs.

3. If the self-test is successful, the Passed screen

appears for one second, the Fail LED turns Off
and the OK LED lights.

F1

Self-Test:
Passed

F2

F3

495-14748

OK

TEST SIG1

SIG2

OOF

NETWORK

RXD

ALRM

SIG

ALRM PDV

OOF

BPV

FAIL

DTR

TXD

CTS

RTS

If the self-test fails, the Failed screen appears for
five seconds. The Fail LED lights, and an
eight-digit failure code (xxxxxxxx) is displayed for
use by service personnel to determine the cause of
the self-test failure. The E1 NTU continues to try
to operate. If you are in doubt about the results of
the self-test, use the Self-Test Health command to
display the status of this test (see the

Self-Test

Health

section in Chapter 4, Maintenance).

F1

Self-Test:
Failed

xxxxxxxx

F2

F3

495-14747

OK

TEST SIG1

SIG2

OOF

NETWORK

RXD

ALRM

SIG

ALRM PDV

OOF

BPV

FAIL

CTS

RTS

TXD

DTR

4. The top-level menu screen appears.

F1

E1 HDSL NTU
Stat

Test

Cnfig

F2

F3

495-14749

OK

TEST SIG1

SIG2

OOF

NETWORK

RXD

ALRM

SIG

ALRM PDV

OOF

BPV

FAIL

DTR

TXD

CTS

RTS