beautypg.com

Test patterns, Sending test patterns – Paradyne ACCULINK 336x E1 User Manual

Page 79

background image

Maintenance

4-21

3360-A2-GB20-20

December 1996

4. From the Loopback Abort screen, press the

desired Function key to abort All or one specific
loopback test. Use the scroll keys, if necessary.

F1

Loopback: Abort
All

LLB

PLB

F2

F3

If you select ALL, LLB, PLB, DLB, or RLB, skip
Step 5.

5. From the Abort screen, press the Function key that

corresponds to the port for which you want to
abort the test. Use the scroll keys, if necessary.

F1

Abort:

Test Name

Prt1

Prt2

Prt3

F2

F3

When abort is complete, the message Command
Complete
appears on the Abort screen.

NOTE

Be careful when selecting a
specific loopback test to abort. If
you mistakenly choose to abort a
loopback test that is not currently
running, a Command Complete
message will still display and the
loopback that is currently active
will still be running. You can use
the TStat branch of the menu to
view the test status to determine if
the abort was successful.

Test Patterns

Use the Test Pattern commands to send, monitor, and

abort test patterns. Available test patterns are:

32767 – A pseudo-random bit sequence (PRBS)
that is 32,767 bits long (on the network only). This
is a PRBS 2

15

–1 test.

511 – A pseudo-random bit sequence (PRBS) that is
511 bits long (on the data ports only). This is a
PRBS 2

9

–1 test.

1-in-8 – A test pattern consisting of a one (1)
followed by seven zeros (on the network only).

QRSS – A quasi-random signal source
approximating live data that can be monitored for
logic errors (on the data ports only).

Sending Test Patterns

Use the Send command to start transmission of a test

pattern.

Only one test pattern can be active at a time on one

port.

Table 4-10

lists the valid send test pattern

combinations. Valid combinations are identified by YES.

To send a test pattern,

1. From the top-level menu screen, select Test.

2. From the Test screen, select Ptrns.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Patterns screen, select Send.

F1

Patterns:
Abort

Send

Mon

F2

F3