Contact is opened. refer to the, G.703 dte interface – Paradyne ACCULINK 336x E1 User Manual

Page 117

background image

ACCULINK 336x E1 NTU

D-2

December 1996

3360-A2-GB20-20

G.703 DTE Interface

The G.703 DTE interface is either two BNC

connectors (Transmit and Receive) for a 75 ohm
unbalanced interface, or a DB15-type socket connector
(

Table D-2

) for a 120 ohm balanced interface. For

information about using Relay Contact Sense for external
DTE loopback, refer to the Extrn DLB configuration
option in the

DTE Interface Configuration Options

section

of Appendix C.

The G.703 DTE cable (

Figure D-1

) is typically

supplied by a DTE vendor. It is made of shielded
twisted-pair wires (22 AWG). The cable connector is a
DB15 plug. Be sure to connect the shield ground only at
the E1 NTU end to prevent ground loops.

Table D-2

G.703 DTE Connector (120 Ohm)

Signal

Pin Number

Receiver Tip from DTE

1

Receiver Ring from DTE

9

Transmitter Tip to DTE

3

Transmitter Ring to DTE

11

Relay Contact Sense Return

12

Relay Contact Sense

14

Shield Ground

2, 4

Figure D-1. G.703 DTE Cable