beautypg.com

Test jacks, Six test jacks are located on the front panel, Section – Paradyne ACCULINK 336x E1 User Manual

Page 72

background image

ACCULINK 336x E1 NTU

4-14

December 1996

3360-A2-GB20-20

Test Jacks

Six test jacks are located on the front panel

(

Figure 4-1

). These test jacks allow for four break-in tests

and two monitor access points to the E1 NTU.

Test jack functions are shown in

Figure 4-2

and

described in

Table 4-8

.

Lp1

Lp2

In

Out

In

Out

HDSL

NET

E1

LINE

E1

MON

495-14753

Figure 4-1. E1 NTU Test Jacks

LINE

INTERFACE

NTU

CIRCUITRY

LINE

INTERFACE

TERMINAL

EQUIPMENT

(DTE)

HDSL

NETWORK

E1

LINE

Out

E1

MON

Out

HDSL

NET

Lp1

E1

LINE

In

E1

MON

In

495-14754

Port 1

Port 2

Port 3

Port 4

HDSL

NET

Lp2

Figure 4-2. Test Jack Block Diagram

Table 4-8

Test Jack Functions

Test Jack Name

Function

HDSL NET Lp1
(HDSL Network Loop 1)

A break-in test jack that allows a signal to be inserted by external test equipment.
The signal is inserted and received on the HDSL (Loop 1) side of the E1 NTU.

HDSL NET Lp2
(HDSL Network Loop 2)

A break-in test jack that allows a signal to be inserted by external test equipment.
The signal is inserted and received on the HDSL (Loop 2) side of the E1 NTU.

E1 LINE In

A break-in test jack that allows an E1 signal to be inserted toward the E1 NTU on
the G.703 DTE side of the E1 NTU.

E1 LINE Out

A break-in test jack that allows an E1 signal to be inserted toward the terminal
equipment on the G.703 DTE side of the E1 NTU.

E1 MON In
(E1 Monitor In)

A monitor jack that nonintrusively monitors the signal coming out of the terminal
equipment on the G.703 DTE side of the E1 NTU.

E1 MON Out
(E1 Monitor Out)

A monitor jack that nonintrusively monitors the signal going into the terminal
equipment on the G.703 DTE side of the E1 NTU.