Self-Test Health

Use the Self-Test Health command to display the

results of the power-up self-test. Possible messages are
listed in

Table 4-1

. See Chapter 2,

Installation

, for more

information about power-up self-test.

To display power-up self-test results,

1. From the top-level menu screen, select Stat.

F1

E1 HDSL NTU
Stat

Test

Cnfig

F2

F3

2. From the Status screen, select STest.

F1

Status:
HDSL DevHS STest

F2

F3

3. View the results of the last power-up self-test. If

no problems were found during power-up, the
following message appears.

F1

SelfTst Health:
Passed

F2

F3

Table 4-1

Self-Test Health Messages

Message

Description

Passed

No problems were found during power-up.

CPU fail

The central processing unit failed internal testing.

Device fail

One or more of the unit’s integrated circuit chips failed to pass internal device level testing.

HDSL fail

The unit failed to successfully test an internal HDSL subassembly.

HDB3/LOS fail

The unit failed to encode data properly or to detect Loss Of Signal.

Alarm fail

The unit failed to transmit AIS or to detect an RAI alarm.

Memory fail

The unit failed program checksum verification.

LCD fail

The front panel liquid crystal display (LCD) failed.

NET Lp1 fail*

The unit failed to internally loop data on the network loop 1 circuit.

NET Lp2 fail*

The unit failed to internally loop data on the network loop 2 circuit.

NET E1 fail

The unit failed to internally loop data on the network E1 circuit.

DTE E1 fail

The unit failed to internally loop data on the DTE E1 circuit.

DSU fail

The unit failed to internally loop data on the DSU.

DSU Port

n fail

Port’s integrated circuitry failed to pass device internal testing.

Unknown Exp Dev

The unit is not able to recognize the expansion device connected to the main circuit card.

Failure

xxxxxxxx

An 8-digit hexadecimal failure code is provided for service personnel.

* Not available on all units.