Displaying e1 ntu test status, Aborting a lamp test – Paradyne ACCULINK 336x E1 User Manual

Page 83

background image

Maintenance

4-25

3360-A2-GB20-20

December 1996

5. The following screens alternately appear on the

LCD until you press a Function key to return to
the Lamp Test screen. In addition, all LEDs blink.

F1

F2

F3

F1

0123456789 : ; < = > ?
@ABCDEFGHIJKLMNO

F2

F3

6. When you are satisfied that all LEDs are lighting

and the LCD is functioning properly, abort the
Lamp test from the Lamp Test screen. If there is
no activity on the E1 NTU front panel for five
minutes, the Device Health and Status screen
appears automatically. However, the Lamp test
remains active until it is aborted.

Aborting a Lamp Test

To abort the Lamp test,

1. Display the Lamp Test screen. To do this when the

LCD is alternating the Lamp test screens, press
any Function key. Otherwise, follow Steps 1
through 3 for starting a Lamp test.

F1

Lamp Test:
Abort

Start

F2

F3

2. From the Lamp Test screen, select Abort.

F1

Lamp Test:
Abort

Start

F2

F3

Displaying E1 NTU Test Status

Use the Test Status command to display the active tests

for the E1 NTU. Status messages that can display on the
front panel LCD are listed in

Table 4-11

.

To display test status,

1. From the top-level menu screen, select Stat.

F1

E1 HDSL NTU
Stat

Test

Cnfig

F2

F3

2. From the Status screen, press the

key until the

TStat selection appears on the screen.

F1

Status:
HDSL DevHS STest

F2

F3

3. Select TStat.

F1

Status:
STest

Perf

TStat

F2

F3

The Test Status screen appears showing you what
tests are active for the E1 NTU.