Patton electronic G.SHDSL INTEGRATED 3086 User Manual
Page 94

4 • Basic Application Configurations
Model 3086 G.SHDSL Integrated Access Device User Guide
94
DSLAM Connections with remote CPE units
3. Go to Configuration Menu > Configuration > WAN connections > Edit (for PPPoH Routed service) >
Edit ‘IP Interface’ > Ipaddr: [enter the WAN IP Address, in this example = 192.168.164.3] > Click on
Change.
4. Configuration Menu > Configuration > IP Routes > Click on Create new Ip V4 Route > Create the gate-
way to the remote 3086 by entering the WAN IP address of the remote 3086, in this example, enter
192.168.164.2 in the Gateway field > OK
The other fields should be:
– Destination:0.0.0.0
– Gateway:192.168.164.2 [already changed in the first part of step 5).]
– Mask:0.0.0.0
– Cost:1
– Interface:[blank]
5. Go to G.SHDSL in the Configuration Menu, then the submenu Status. The Modem State should be
“deactivated.” (If not, go to the Action and change it to deactivate.)
Then in the Action submenu under G.SHDSL, change Action to Start, then click on
Action
.