Model 3086 G.SHDSL Integrated Access Device User Guide

4 • Basic Application Configurations

Switch S2-8. S2-8 activates configuration of Model 3086 via DIP switches. Any time the user desires to mod-
ify the 3086 configuration available through DIP switches, make the changes to the corresponding switches
and then set S2-8, from On to Off position, wait 3-4 seconds and set back to the On position. Changes made
to configuration via DIP switches will not take effect if S2-8 isn’t toggled.

Switch Bank S3
The table below shows the default configuration for switch S3. A description of S3 options follows this table.

Switch S3-1: CO/CP selection. CO and CP stand for Central Office and Customer Premise respectively.
When deploying the model 3086s, units installed at the Customer location should be set to CP and units

On

On

Off

On

On

Off

Off

1216

On

On

Off

On

Off

On

On

1280

On

On

Off

On

Off

On

Off

1344

On

On

Off

On

Off

Off

On

1408

On

On

Off

On

Off

Off

Off

1472

On

On

Off

Off

On

On

On

1536

On

On

Off

Off

On

On

Off

1600

On

On

Off

Off

On

Off

On

1664

On

On

Off

Off

On

Off

Off

1728

On

On

Off

Off

Off

On

On

1792

On

On

Off

Off

Off

On

Off

1856

On

On

Off

Off

Off

Off

On

1920

On

On

Off

Off

Off

Off

Off

1984

On

Off

On

On

On

On

On

2048

S2-8

Condition

ON->Off->ON

Implements switch configuration (toggled ON/OFF)

Table 8. S3 Summary Table

Switch Position

Function

Factory Default

Selected Option

S3-1

CO/CP Selection

On

CO

S3-2

Reserved

On

Reserved

S3-3

Clock

On

External

S3-4

Reserved

On

Reserved

S3-5

Reserved

On

Reserved

S3-6

Annex

Off = Annex A

On = Annex B

Annex B

S3-7

T1/E1

On

T1

S3-8

E1/CRC

On

No CRC

S7

S6

S5

S4

S3

S2

S1

Data Rate (kbps)