beautypg.com

No rmon alarm – Panasonic 470 User Manual

Page 87

background image

no rmon alarm

87

Parameters and variables

Description

<1-2147483647>

The sampling interval in seconds.

absolute

Use absolute values (value of the
MIB object is compared directly with
thresholds).

delta

Use delta values (change in value of
the MIB object between samples is
compared with thresholds).

rising-threshold

<-2147483648-2147483647>

[<1-65535>]

The first integer value is the rising
threshold value. The optional second
integer specifies the event entry
triggered when the rising threshold
is crossed. If omitted, or if an invalid
event entry is referenced, no event is
triggered.

falling-threshold

<-2147483648-2147483647>

[<1-65535>]

The first integer value is the falling
threshold value. The optional second
integer specifies the event entry
triggered when the falling threshold
is crossed. If omitted, or if an invalid
event entry is referenced, no event is
triggered.

[owner ]

Specifies an owner string to identify
alarm entry.

no rmon alarm

The

no rmon alarm

command deletes RMON alarm table entries. When

the variable is omitted, all entries in the table are cleared. The syntax for
the

no rmon alarm

command is:

no rmon alarm [<1-65535>]

The

no rmon alarm

command is in the config command mode.

Table 34 "no rmon alarm command parameters and variables" (page 87)

describes the parameters and variables for the

no rmon alarm

command.

Table 34
no rmon alarm command parameters and variables

Parameters and variables

Description

<1-65535>

Unique index for the alarm entry.

Nortel Ethernet Switch 460/470

Configuration — System Monitoring

NN47210-503

01.01

Standard

3.7

22 February 2007

Copyright © 2005-2007, Nortel Networks

Nortel Networks Confidential

.