Panasonic 470 User Manual
Page 78
78
Chapter 4 Configuring network monitoring using Web-based management
Figure 26
Ethernet Errors page
Table 30 "Ethernet Errors page items" (page 78)
describes the items
on the Ethernet Errors page.
Table 30
Ethernet Errors page items
Item
Description
Port
The port number corresponding to the selected switch.
Alignment Errors
The number of frames received on a particular interface that are not an
integral number of octets in length and do not pass the FCS check.
FCS Errors
The number of frames received on a particular interface that are an
integral number of octets in length, but do not pass the FCS check.
Internal MAC
Transmit Errors
The number of frames for which transmission on a particular interface
fails due to an internal MAC sublayer transmit error. A frame is added
to this counter only if it is not counted as a late collision error, excessive
collisions error, or as a carrier sense error.
Internal MAC Receive
Errors
The number of frames for which reception on a particular interface fails
due to an internal MAC sublayer transmit error. A frame is added to
this counter only if it is not counted as a late collision error, excessive
collisions error, or as a carrier sense error.
Carrier Sense Errors
The number of times that the carrier sense conditions were lost or never
asserted when attempting to transmit a frame on a particular interface.
Frame Too Long
The number of frames received on a particular interface that exceed
the maximum permitted frame size.
Nortel Ethernet Switch 460/470
Configuration — System Monitoring
NN47210-503
01.01
Standard
3.7
22 February 2007
Copyright © 2005-2007, Nortel Networks
Nortel Networks Confidential
.