Table 21 ethernet errors tab fields, Figure 19 "graph port dialog box – Panasonic 470 User Manual
Page 60
60
Chapter 3 Configuring network monitoring using Device Manager
Figure 19
Graph Port dialog box -- Port Ethernet Errors tab
—End—
Table 21 "Ethernet Errors tab fields" (page 60)
describes the Port Ethernet
Errors tab fields.
Table 21
Ethernet Errors tab fields
Field
Description
AlignmentErrors
A count of frames received on a particular
interface that are not an integral number of octets
in length and do not pass the FCS check. The
count represented by an instance of this object
is incremented when the alignmentError status
is returned by the MAC service to the LLC (or
other MAC user). Received frames for which
multiple error conditions occur are, according to
the conventions of IEEE 802.3 Layer Management,
counted exclusively according to the error status
presented to the LLC.
FCSErrors
A count of frames received on a particular interface
that are an integral number of octets in length but
do not pass the FCS check. The count represented
by an instance of this object is incremented when
the Frame Check Error status is returned by the
MAC service to the LLC (or other MAC user).
Received frames for which multiple error conditions
occur are, according to the conventions of IEEE
802.3 Layer Management, counted exclusively
according to the error status presented to the LLC.
InternalMacTransmitErro
rs
A count of frames for which transmission on a
particular interface fails due to an internal MAC
sublayer transmit error. A frame is only counted by
an instance of this object if it is not counted by the
corresponding instance of either the LateCollisions
object, the ExcessiveCollisions object, or the
CarrierSenseErrors object.
Nortel Ethernet Switch 460/470
Configuration — System Monitoring
NN47210-503
01.01
Standard
3.7
22 February 2007
Copyright © 2005-2007, Nortel Networks
Nortel Networks Confidential
.