3 • Running Mail

SV62276 Rev. A

Entering Weight Manually

This procedure can be used when you already know the weight of a

mail piece and you are not using the integrated weighing platform.
1. Press

Weigh/Rate.

2. Select “Enter Manual Weight”.

3. Key in pounds and select “Set Pounds” (maximum is 70 lbs.).
4. Key in ounces and select “Set oz and Continue”.
5. Select the desired class by pressing the key next to the class

name (use the scroll keys to see additional classes).

6. If there is no value next to the class name, more information

is needed. Follow the prompts for the options and/or services

available for this class of service. The last screen is usually "Ser-

vices" and lists special services such as COD and Insurance.

i

NOTE:

If you are unsure if a particular class is valid for your

mail piece, call your local post office or visit

www.USPS.com.

0 lb 0.0oz

Place mail on scale

◄Enter manual weight

◄Diff. weighing

9. Place the envelope up against the

registration wall of the system and

slide it to the right until the system

grasps it. The system prints the me-

ter stamp and ejects the envelope/

tape sheet.

8. If using the moistener, place flap

along moistener and move towards

the right.

7. Select "Done" when finished entering all the class options and fees.

Applying Postage