X.25 cause codes and diagnostic codes, Standard reset indication cause codes – Kentrox AI296 User Manual
Page 384

A-2
AI296 Version 9.8x User’s Guide
AI296 System Codes: X.25 Cause Codes and Diagnostic Codes
X.25 Cause Codes and Diagnostic Codes
X.25 cause codes indicate events that triggered X.25 packets. Possible values for the
cause codes can vary depending on the type of packet (CLEAR REQUEST,
REGISTRATION CONFIRMATION, RESET REQUEST, or RESTART).
X.25 diagnostic codes provide additional tips about the nature of a specific problem.
Unlike cause codes, diagnostic codes do not vary depending on the type of packet.
Note: Diagnostic codes can be produced by any equipment that handles virtual
circuits and can propagate through all equipment that handles virtual circuits.
Because of this, diagnostic codes may not indicate a problem with AI296.
The following X.25 cause codes and diagnostic codes are available:
z
Standard Reset Indication Cause Codes
z
Kentrox-Specific Reset Indication Cause Codes
z
Standard Clear Indication Cause Codes
z
z
z
Kentrox-Specific Diagnostic Codes
Standard Reset Indication Cause Codes
Reset indication cause codes apply to reset packets.
lists the standard
reset indication cause codes (in hexadecimal format) and their meanings.
Table A-1 Standard Reset Indication Cause Codes
Cause Code
Description
0x00
Remote DTE originated reset
0x01
Reset out of order
0X03
Reset due to remote procedure error
0X05
Reset due to local procedure error
0X07
Reset due to network congestion
0X09
Reset due to remote DTE operational
0X0F
Reset due to network operational
0X11