Configuration in the ai296 local menu system – Kentrox AI296 User Manual
Page 177
AI296 Version 9.8x User’s Guide
Link Configuration: X.25 Parameters Configuration
6-83
Configuration in the AI296 Local Menu System
1. Access the X.25 Link Menu.
2. Select
X.25 Parameters Menu
. The X.25 Parameters Menu appears.
3. For
T20 Restart Timer
, enter the timer value. The default is
180000
.
4. For
T21 Call Timer
, enter the timer value. The default is
200000
.
5. For
T22 Reset Timer
, enter the timer value. The default is
10000
.
6. For
T23 Clear Timer
, enter the timer value. The default is
180000
.
7. For
T24 Window Timer
, enter the timer value. The default is
75000
.
8. For
T25 Data Retransmission Timer
, enter the timer value. The default is
150000
.
9. For
T26 Interrupt Timer
, enter the timer value. The default is
180000
.
10. For
T28 Registration Timer
, enter the timer value. The default is
180000
.
This example displays:
z
T20 Restart Timer
set to
1750000
z
T21 Call Timer
set to
1000000
z
T22 Reset Timer
set to
20000
z
T23 Clear Timer
set to
180000
z
T24 Window Timer
set to
2356000
z
T25 Data Retransmission Timer
set to
1650000
z
T26 Interrupt Timer
set to
2300000
z
T28 Registration Timer
set to
90000
.
X.25 Parameters Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03
X25 Facilities Negotiation . . . . . . . . . . . . . Enabled [Disabled]
Max Packet Size . . . . . . . . . . . . . . . . . . . . [128] 256 512
Packet Window Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
X121 Local Address . . . . . . . . . . . . . . . . . . . . . ................
T20 Restart Timer . . . . . . . . . . . . . . . . . . . . . . . . . . .1750000
T21 Call Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000000
T22 Reset Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 20000
T23 Clear Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180000
T24 Window Timer . . . . . . . . . . . . . . . . . . . . . . . . . . .2356000
T25 Data Retransmission Timer . . . . . . . . . . . . . . . . . . . . .1650000
T26 Interrupt Timer . . . . . . . . . . . . . . . . . . . . . . . . . .2300000
T28 Registration Timer . . . . . . . . . . . . . . . . . . . . . . . .. 90000