General link properties configuration, Auto disable error limit, General link properties configuration -23 – Kentrox AI296 User Manual
Page 117: Auto disable error limit -23

AI296 Version 9.8x User’s Guide
Link Configuration: General Link Properties Configuration
6-23
General Link Properties Configuration
General link properties are configurable using menus accessed directly from the link
configuration menu. The following configuration items are available:
Auto Disable Error Limit
Description
This menu item disables a link when the rate of errors received on that link exceeds a
user-specified threshold. This prevents a bad link or cable from streaming enough
errors to lock up or crash AI296.
Menu Item Type
Data
Link Type Availability
Async, AsyncPPP, HDLC-Bridge, MLT, SyncPPP, and X.25
Configuration in the AI198 Menu System
1. Access Menu 4.2.11.12.
2. For
Auto Disable Error Limit
, enter the associated item number, a comma, and the
error limit value. (For example,
9,25000
.) The default is
0
.