Symbol Technologies Spectrum24 AP-4131 User Manual
Page 71
Configuring the AP
AP-4131 Access Point Product Reference Guide
61
Ethernet
Timeout
Disables radio interface if no activity is detected
on the Ethernet line after the seconds indicated
(
30-255
). The AP disassociates MUs and prevents
further associations until it detects Ethernet activity.
The default value
0
disables this feature. The
1
value detects if the 10/100Base-T line goes down.
If the value is set to
2
and the WLAP has
connected to the Root AP, the WLAP sends a WLAP
Alive BPDU on the Ethernet line every WLAP Hello
Time seconds to allow WLAPs on the Ethernet line
to detect its existence.
If the value is set to
3
, the WLAP tracks the WLAP
Alive BPDU. If the BPDU is missing for WLAP Hello
Time seconds, the WLAP state changes to WLAP
Lost on Ethernet. Once the WLAP Alive BPDU is
detected, the WLAP resets and starts over.
When the Ethernet connection is broken the AP
clears the MU table and disables the RF interface
until the Ethernet connection comes up.
Telnet Logins
Specifies if the AP accepts or rejects Telnet Logins.
The default value is
Enabled
.