Symbol Technologies Spectrum24 AP-4131 User Manual
Page 54
Configuring the AP
44
AP-4131 Access Point Product Reference Guide
To ensure the
Web Server
option is enabled for the AP:
1. Access the UI using a Serial or Telnet connection.
2. From the
Main Menu
select
System Configuration
.
3. Verify the
Web Server
option on the
System Configuration
screen
is enabled.
4. Select
Save-[F1]
to save the configuration.
To reset the AP for changes to take effect.
1. Select the
Special Functions
screen.
2. Select
Reset AP.
3. Select
Yes
at the confirmation prompt.
To enable Help file access, change the Help URL parameter:
1. Select the
Special Functions
screen
2. Press F3 to view the
Firmware Functions
Update Menu.
3. Use the TAB or UP/DOWN ARROW key to select the
Alter Filename(s)/HELP
URL/TFTP Server
.
4. Press ENTER.
5. Use the TAB or DOWN ARROW key to select the
.HELP URL
field.
6. Type the IP address/URL (Universal Request Locator) of the Web server
and the directory/folder of the Web server for the Help file location.
http://xxx.xxx.xxx.xxx/WebHelp
Where xxx.xxx.xxx.xxx is the IP address of the server.
7. Save the new setting by selecting
Save-[F1]
option
.
8. Select
Yes
at the confirmation prompt.