background image

Hardware Information

7-32

SIMATIC Box PC 620 Manual

A5E00131465-01

7.6.2

ISA Slot Pin Assignment

Pin

Designation

Type* Pin

Designation

Type

A1

–IOCHCK

I

B1

0 V

GND

A2

SD 07

I/O

B2

RESET DRV

O

A3

SD 06

I/O

B3

+ 5V

V

CC

A4

SD 05

I/O

B4

IRQ 9

I

A5

SD 04

I/O

B5

– 5V

V

CC

A6

SD 03

I/O

B6

reserved

I

A7

SD 02

I/O

B7

– 12V

V

CC

A8

SD 01

I/O

B8

reserved

I

A9

SD 00

I/O

B9

+ 12V

V

CC

A10

–IOCHRDY

I

B10

0 V

GND

A11

AEN

O

B11

–SMEMW#

O

A12

SA 19

I/O

B12

–SMEMR#

O

A13

SA 18

I/O

B13

–IOW#

I/O

A14

SA 17

I/O

B14

–IOR#

I/O

A15

SA 16

I/O

B15

–DACK3#

O

A16

SA 15

I/O

B16

DRQ 3

I

A17

SA 14

I/O

B17

–DACK1#

O

A18

SA 13

I/O

B18

DRQ 1

I

A19

SA 12

I/O

B19

–REFRESH#

I/O

A20

SA 11

I/O

B20

CLK

O

A21

SA 10

I/O

B21

IRQ 7

I

A22

SA 09

I/O

B22

reserved

I

A23

SA 08

I/O

B23

IRQ 5

I

A24

SA 07

I/O

B24

IRQ 4

I

A25

SA 06

I/O

B25

IRQ 3

I

A26

SA 05

I/O

B26

reserved

O

A27

SA 04

I/O

B27

TC

O

A28

SA 03

I/O

B28

BALE

O

A29

SA 02

I/O

B29

+ 5V

V

CC

A30

SA 01

I/O

B30

OSC

O

A31

SA 00

I/O

B31

0 V

GND

*)

I/O determines the direction of the signals for the CPU board.

#