beautypg.com

Siemens Simatic 620 User Manual

Page 159

background image

Hardware Information

7-27

SIMATIC Box PC 620 Manual

A5E00131465-01

Port to the Floppy Disk Drive

This port is intended for the connection of a notebook floppy disk drive. The
maximum connection length of the data cable may not exceed 40cm.

Pin no.

Designation

Description

Input/Output

1

P5V

+5V

Output

2

INDEX_N

Index hole recognition

Input

3

P5V

+5V

Output

4

DS_N0

Drive 0 selection

Output

5

P5V

+5V

Output

6

DCHG_N

Disk change display

Input

7

n.c.

not connected

-

8

n.c.

not connected

-

9

Reserved

reserved

-

10

MOT_N0

Activate motor 0

Output

11

Reserved

reserved

-

12

DIR_SL_N

Step motor direction

Output

13

n.c.

not connected

-

14

STEP_N

Step motor pulse

15

GND

Ground

-

16

WR_DAT_N

Write data signal

Output

17

GND

Ground

-

18

WR_GAT_N

Enable data signal

Output

19

Reserved

reserved

-

20

TRACK_N0

Track 0 signal

Input

21

Reserved

reserved

-

22

WR_PRT_N

Write protection signal

Input

23

GND

Ground

-

24

RD_DAT_N

Read Data signal

Input

25

GND

Ground

-

26

SIDE_1_N

Page selection

Output

Assignment of the IDE Ports

The primary IDE port is intended for the alternative installation of
2.5” and 3.5” hard disks. 3.5” drives are connected via a 40 pin 2.54mm latching
connector, 2.5” drives via a 44 pin 2mm latching connector. The two connectors
are connected in parallel. The secondary IDE port is intended for the optional
connection of a CD ROM and / or an LS 240 drive. It is adaptable via a 44 pin
2mm latching connector. The maximum connection length of the data cables may
not exceed 40cm.