Siemens Simatic 620 User Manual
Page 152
Hardware Information
7-20
SIMATIC Box PC 620 Manual
A5E00131465-01
Display Port (LVDS)
TFT displays with an LVDS port can be connected to this port. The connection of
18 bit displays up to a resolution of 1024x768 pixels is possible. The permissible
display clock rate is 20MHz to 66Mhz. The display is selected automatically in
accordance with the coding of the Select Inputs display. The display supply
voltages (3.3V and 5V) are connected via the graphic controller, dependent on the-
requirements of the connected displays. The maximum cable length is 50cm with a
transmission rate of 455MHz. Special cable properties are to be considered for the
pair of differential cables in accordance with the LVDS specification.
Pin No.
Designation
Description
Input / Output
1
P5V_D_fused
+5V (fused) VCC display
Output
2
P5V_D_fused
+5V (fused) VCC display
Output
3
RXIN0–
LVDS output signal bit 0 (-)
Output
4
RXIN0+
LVDS output signal bit 0 (+)
Output
5
P3V3_D_fused
+3.3V (fused) VCC display
Output
6
P3V3_D_fused
+3.3V (fused) VCC display
Output
7
RXIN1–
LVDS output signal bit 1 (-)
Output
8
RXIN1+
LVDS output signal bit 1 (+)
Output
9
GND
Ground
-
10
GND
Ground
-
11
RXIN2-
LVDS output signal bit 2 (-)
Output
12
RXIN2+
LVDS output signal bit 2 (+)
Output
13
GND
Ground
-
14
GND
Ground
-
15
RXCLKIN-
LVDS clock pulse (-)
Output
16
RXCLKIN+
LVDS clock pulse (+)
Output
17
GND
Ground
-
18
GND
Ground
-
19
Reserved
20
Reserved