beautypg.com

Siemens Simatic 620 User Manual

Page 155

background image

Hardware Information

7-23

SIMATIC Box PC 620 Manual

A5E00131465-01

Internal Serial Port COM2 (V.24)

This port is connected in parallel to the external COM2 port. Both ports can
therefore only be used alternatively. The assignment is executed in such a way
that a 1:1 connection to a 9 pin subminiature Cannon socket can be made when
using insulation piercing connecting devices. The maximum cable length is 100cm
with a data transfer rate of 9.6 Kbps.

Pin No.

Designation

Description

Input / Output

1

DCD

Receiving signal level

Imput

2

DSR

Readiness for operation

Input

3

RxD

Received data

Input

4

RTS

Switch on transmitter

Output

5

TxD

Transmitted data

Output

6

CTS

Ready to transmit status

Input

7

DTR

Terminal ready

Input

8

RI

Incoming call

Input

9

GND

Functional ground (reference

potential)

-

10

P5V

+5V power supply

Output

7.5.3

Assignment of the Internal Ports on the Motherboard

Port

Position

Connector Description

Memory

internal

X19, X20

2 SO-DIMM slot, 64Bit

Processor

internal

X1

Socket for MMC2 mobile processor

Bus extender

internal

X10

Socket for bus extender, assigned with ISA

and PCI bus signals

Power supply

105W

internal

X13

20 pin connector for DC signals of the power

supply unit with 85W

Power supply

85W

internal

X14

40 pin connector for DC signals of the power

supply unit with 85W

Floppy

internal

X5

two drives are possible (82078 compatible)

360kB, 720kB, 1.2MB, 1.44MB

3F0h-3F7h, 370h-377h, can be disabled

IRQ 6, edge-triggered

26 pin, socket for flex-lead (notebook

connection)

3.5” hard disk

internal

X41

170h-177h, 1F0h-1F7h, can be disabled

IRQ14, IRQ15, edge-triggered

40 pin, 2.54mm male connector

(3.5” HD, primary),

a maximum of two drives are operable