Siemens Simatic 620 User Manual
Page 155
Hardware Information
7-23
SIMATIC Box PC 620 Manual
A5E00131465-01
Internal Serial Port COM2 (V.24)
This port is connected in parallel to the external COM2 port. Both ports can
therefore only be used alternatively. The assignment is executed in such a way
that a 1:1 connection to a 9 pin subminiature Cannon socket can be made when
using insulation piercing connecting devices. The maximum cable length is 100cm
with a data transfer rate of 9.6 Kbps.
Pin No.
Designation
Description
Input / Output
1
DCD
Receiving signal level
Imput
2
DSR
Readiness for operation
Input
3
RxD
Received data
Input
4
RTS
Switch on transmitter
Output
5
TxD
Transmitted data
Output
6
CTS
Ready to transmit status
Input
7
DTR
Terminal ready
Input
8
RI
Incoming call
Input
9
GND
Functional ground (reference
potential)
-
10
P5V
+5V power supply
Output
7.5.3
Assignment of the Internal Ports on the Motherboard
Port
Position
Connector Description
Memory
internal
X19, X20
2 SO-DIMM slot, 64Bit
Processor
internal
X1
Socket for MMC2 mobile processor
Bus extender
internal
X10
Socket for bus extender, assigned with ISA
and PCI bus signals
Power supply
105W
internal
X13
20 pin connector for DC signals of the power
supply unit with 85W
Power supply
85W
internal
X14
40 pin connector for DC signals of the power
supply unit with 85W
Floppy
internal
X5
two drives are possible (82078 compatible)
360kB, 720kB, 1.2MB, 1.44MB
3F0h-3F7h, 370h-377h, can be disabled
IRQ 6, edge-triggered
26 pin, socket for flex-lead (notebook
connection)
3.5” hard disk
internal
X41
170h-177h, 1F0h-1F7h, can be disabled
IRQ14, IRQ15, edge-triggered
40 pin, 2.54mm male connector
(3.5” HD, primary),
a maximum of two drives are operable