16 configuration jumpers, 17 system recovery and update jumpers – Intel SE7525GP2 User Manual
Page 161

Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS Connector Definitions and Pin-Outs
Revision 2.0
161
Table 92 . Six-pin Fan headers Pin-out (J44, J46)
Pin
Signal Name
Type
Description
1
Ground
Power
GROUND is the power supply ground
2
Fan Power
Power
Fan Power
3
Fan Tach
Out
FAN_TACH signal is connected to the Super IO to monitor the FAN
speed.
4
Fan PWM
Out
Fan speed control
5 N/C
6 N/C
7.15.2 Intrusion
Cable
Connector
Table 93. Intrusion Cable Connector (J19) Pin-Out
Pin
Signal Name
1 INTRUDER_N
2 GND
7.15.3 SCSI
LED
Header
Table 94. SCSI LED Header Pin-out (J26)
Pin
Signal Name
Description
1 GND
Ground
2 SCSI_CONN_LED_N
Activity
Signal
3 SCSI_CONN_LED_N
Activity
Signal
4 GND
Ground
7.16 Configuration Jumpers
This section describes the configuration jumpers on the Intel Server Board SE7320SP2 and
Intel Server Board SE5725GP2.
7.17 System Recovery and Update Jumpers
The Intel Server Board SE7320SP2 and Intel Server Board SE7525GP2 provide an 11-pin
single inline header (J17), located on the edge of the server board next to PCI Slot 1, this
header provides a total of three 3-pin jumper blocks that are used to configure several system
recovery and update options. Figure 19 shows the factory default locations for each jumper
option.