Table 50. mBMC Factory Default Event Filters

Event Filter #

Offset Mask

Events

1 Non-critical

Voltage

Assert

2 Non-critical

Voltage

Deassert

3 Critical

Voltage

Assert

4 Critical

Voltage

Deassert

5

Critical

PS Soft Fail Assert

6

Critical

PS Soft Fail Deassert

7

Critical

Proc 1-2 Thermal Trip Assert

8

Critical

Proc 1-2 Thermal Trip, Config Error & IERR Deassert

9

Degraded

Proc 1-2 FRB3 Assert

10

Degraded

Proc 1-2 FRB3 Deassert

11

Degraded

Proc 1-2 Hot Assert

12

Degraded

Proc 1-2 Hot Deassert

13

Critical

FP NMI Assert

14

Critical

FP NMI Deassert

15

Non Critical

SCSI Terminator Fail Assert

16

Non Critical

SCSI Terminator Fail Deassert

17

N/A

ID Button Assert

18

N/A

ID Button Deassert

19

Critical

Fan Speed Assert

20

Critical

Fan Speed Deassert

21

Non Critical

Fan Speed Assert

22

Non Critical

Fan Speed Deassert

23 Critical

Temperature

Assert

24 Critical

Temperature

Deassert

25

Non Critical

Temperature Assert

26

Non Critical

Temperature Deassert

27

Critical

Proc 1-2 IERR Assert

28

Critical

CPU Configuration Error

29

N/A

Reserved for ISM

30

N/A

Reserved for ISM

5.2.12.2

Alert over LAN

LAN alerts are sent as SNMP traps in ASF formatted Platform Event Traps to a specified alert
destination. The Alert over LAN feature is used to send either Platform Event Trap alerts or
directed events to a remote system management application, regardless of the state of the
host’s operating system. LAN alerts may be sent over the LAN channel specified for the
platform. LAN alerts can be used by PEF to send out alerts to selected destination when ever
an event matches an event filter table entry For more information on LAN alerts, see the IPMI
Specification v1.5
.