Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS

Platform Management

Revision 2.0

120

5.3.1.1 Power-up

Sequence

When turning on the system power in response to one of the event occurrences listed in
Table 51 below, the mBMC executes the following procedure:

1. The mBMC asserts Power On and waits for the power subsystem to assert Power

Good. The system is held in reset.

2. The mBMC sends a Set ACPI Power State command, indicating an S0 state to all

management controllers whose SDR management device records indicate that they
should receive the notification.

3. The mBMC initializes all sensors to their Power On initialization state. The Init Agent is

run.

4. The mBMC attempts to boot the system by running the FRB algorithm.

5.3.1.2 Power-down

Sequence

To power down the system, the mBMC effectively performs the sequence of power-up steps in
reverse order. This operation can be initiated by one of the event occurrences listed in Table 51
and proceeds as follows:

1. The mBMC asserts system reset (de-asserts Power Good).
2. If enabled, the mBMC sends a Set ACPI Power State command, indicating an S0 state

to all management controllers whose SDR management device records indicate that
they should receive the notification.

3. The mBMC de-asserts the Power On signal.
4. The power subsystem turns off system power upon de-assertion of the Power On

signal.

5.3.1.3

Power Control Sources

The sources listed in the following table can initiate power-up and/or power-down activity.

Table 51: Power Control Initiators

#

Source

External Signal Name or

Internal Subsystem

Capabilities

1

Power Button

FP Power button

Turns power ON or OFF

2

mBMC Watchdog Timer

Internal mBMC timer

Turns power OFF, or power cycle

3

Platform Event Filtering

PEF

Turns power OFF, or power cycle

4

Command

Routed through command processor

Turns power ON or OFF, or power cycle

5

Power state retention

Implemented via mBMC internal logic

Turns power ON when AC power returns

6

Chipset

sleep S5

Turns power ON or OFF

5.3.2

System Reset Control

5.3.2.1

Reset Signal Output

The mBMC asserts the System Reset signal on the server board to perform a system reset. The
mBMC asserts the System Reset signal before powering the system up. After power is stable
(as indicated by the power subsystem Power Good signal), the mBMC sets the processor
enable state as appropriate and de-asserts the System Reset signal, taking the system out of
reset.