beautypg.com

4 light guided diagnostics – Intel SE7525GP2 User Manual

Page 145

background image

Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS

Error Reporting and Handling

Revision 2.0

145

6.3.8

Memory Error Codes

Table 68: Memory Error Codes

Tpoint

Description

001h MEM_ERR_CHANNEL_B_OFF

(DIMM mismatch forced Channel B disabled)

002h MEM_ERR_CK_PAIR_OFF

(Slow DIMM(s) forced clock pair disabled)

0E1h MEM_ERR_NO_DEVICE

(No memory installed)

0E2h MEM_ERR_TYPE_MISMATCH
0E3h MEM_ERR_UNSUPPORTED_DIMM

(Unsupported DIMM type)

0E4h MEM_ERR_CHL_MISMATCH
0E5h MEM_ERR_SIZE_MISMATCH
0E6h MEM_ERR_ECC_MISMATCH
0E8h MEM_ERR_ROW_ADDR_BITS
0E9h MEM_ERR_INTERNAL_BANKS
0EAh MEM_ERR_TIMING
0EBh MEM_ERR_INST_ORDER_ERR
0ECh MEM_ERR_NONREG_MIX
0EDh MEM_ERR_LATENCY
0EEh MEM_ERR_NOT_SUPPORTED
0EFh MEM_ERR_CONFIG_NOT_SUPPORTED
0F0h SYS_FREQ_ERR

(Flag for Unsupported System Bus Freq)

0F1h DIMM_ERR_CFG_MIX

(Usupported DIMM mix)

0F2h DQS_FAILURE

(indicates DQS failure)

0F3h MEM_ERR_MEM_TEST_FAILURE

(Error code for unsuccessful Memory Test)

0F4h MEM_ERR_ECC_INIT_FAILURE

(Error code for unsuccessful ECC and Memory Initialization)

6.4 Light Guided Diagnostics

The server board provides system fault/status LEDs in many areas of the board to alert users to
a particular failure or status of a component on the board. There are fault LEDs for the memory
DIMMs and processors, and status LEDs for 5-volt stand-by and system state.